The 3D printer features high speed and
high utilization rate. Although the digital operation mode has low fault rate,
if the fault appears, it will not only affect the printing quality, but also
waste time and filaments, and even damage the machine. At present, the most
common fault of 3D printer is that the nozzle is blocked and cannot discharge.
There are several reasons and solutions about nozzle fault. Given below are
some of the reasons for nozzle blockage and their solutions:-
Reason 1
The residual filaments solidify and
block the nozzle because the nozzle is not cleaned in time after printing.
Solution 1
First, heat the nozzle to the normal
melting temperature of printing consumables; then try to insert the wire into
the nozzle manually. Normally, the downward pressure of manual feeding can
penetrate the consumable line and bring out the blocked debris;
Finally, if the nozzle still fails to
work, try to use a 1.5mm hexagonal wrench to dredge the throat or nozzle.
(Notice: After printing, be sure empty the sprinkler to at the first time to avoid blocking.)
Reason 2
The consumable is broken and stuck in
the conduit during the feeding process, which affects the feeding.
Solution 2
Take out the filament and cut off the
damaged part of the consumable;
Then put the filament in again, pay
attention to keep the smoothness of the filament.
Reason 3
The impurity consumables are easy to
swell, which affects the normal discharge of the nozzle.
Solution 3
High-quality consumables are
recommended to avoid damaging the machine.
Reason 4
The heating temperature of the nozzle is not up to the standard temperature, so that the nozzle cannot be worked
Solution 4
Temperature parameters: if the heating
temperature is set correctly and the nozzle is not heated normally, check
whether the heating rod, heating resistance improper contact of circuit: check
whether the nozzle heating temperature matches the consumable melting
temperature; (notice: the temperature of ABS printing nozzle is between 210 ℃ - 230 ℃, and that
of PLA printing nozzle is between 195 ℃ - 220 ℃.) and
other circuits are in poor contact; if the cause cannot be found, it is
recommended to turn off the power immediately and contact the after-sales
engineer for solution.
(Notice: Different brands have own
quality control, and the service life of the nozzle is different)
No comments: